MK-1203B ECG Machine
Product Description

Accurate ECG Acquisition
The MK-1203B captures all 12 leads at once and records 3 channels—ideal for clinical screening and preliminary arrhythmia analysis. High-performance acquisition circuitry and defibrillation protection keep real ECG waveforms clear, even under complex clinical electromagnetic interference.
- High common-mode rejection circuit effectively suppresses on-site electromagnetic interference
- Multi-level digital filters wipe out myoelectric and power-frequency interference plus baseline drift
- Real-time lead-off detection alerts abnormal electrode connections

Compact & Practical Human-Centered Design
Lightweight main unit with a keypad operation panel. The 4.3-inch TFT color LCD plays back all 12-lead ECG waveforms in real time. A built-in thermal printer removes the need for external printing devices. The high-capacity rechargeable battery powers field operations without AC supply—ready for multi-scenario mobile examinations.

Local Storage & Data Connectivity
The device stores up to 200 complete patient ECG reports locally, so waveform and report review and re-printing are always at hand. USB and RS232 dual communication interfaces support external-system docking, ECG-data export, and archiving—keeping departmental digital medical-record management smooth.

Multi-Mode Workflow for Clinical Efficiency
Manual, Auto, and Rhythm Analysis modes cover routine physical examinations and long-duration rhythm capture. Built-in auto-interpretation reference reports help medical staff read waveforms fast, cutting operating steps and lifting bedside and outpatient-examination efficiency.
Features
- 4.3-inch TFT color LCD display with 480×272 resolution for simultaneous 12-lead ECG waveform viewing
- 12-lead synchronous ECG acquisition; 3-channel thermal recording with rhythm-lead output
- Multiple working modes: Manual / Auto / Rhythm Analysis
- Multi-grade digital filters: EMG filter, AC-interference filter, baseline-drift suppression
- Real-time lead-off detection and prompt function
- Built-in thermal printer compatible with 80 mm width roll thermal paper
- Local storage for 200 patient cases; supports review and re-print
- Built-in 6000 mAh rechargeable lithium-ion battery for up to 4-hour continuous operation
- Dual AC-DC power supply: wide-voltage AC input 110–230 V, 50/60 Hz
- USB & RS232 communication interfaces for ECG-data export
- Defibrillation protection for enhanced clinical safety
Specifications
Display
| Item | Parameter |
|---|---|
| LCD | 4.3-inch diagonal TFT color LCD |
| Resolution | 480 × 272 pixels |
ECG Acquisition
| Item | Parameter |
|---|---|
| Lead System | Standard 12-lead ECG, 3-channel output recording |
| Sampling Rate | ≥8000 samples per second per channel |
| CMRR | ≥103 dB (AC filter enabled) |
| Input Impedance | >10 MΩ |
| Frequency Response | 0.05 Hz–160 Hz |
| Time Constant | ≥3.2 s |
| Noise Level | ≤30 μV peak-to-peak |
| Defibrillation Protection | Supported |
| Patient Leakage Current | <10 μA |
Recording & Printing
| Item | Parameter |
|---|---|
| Printer Type | Built-in thermal printer |
| Paper Specification | 80 mm ×20 m roll thermal paper |
| Paper Speed | 5 / 6.25 /10 /12.5 /25 /50 mm/s |
| Sensitivity(Gain) | 1.25 /2.5 /5 /10 /20 /40 mm/mV (auto/manual selectable) |
| Record Mode | 12-lead full print, rhythm-lead recording, arrhythmia-analysis recording |
Filter System
| Item | Parameter |
|---|---|
| AC Filter | 50 Hz / 60 Hz(-20 dB) |
| EMG Filter | 25 /35 /45 /75 /100 Hz(-3 dB) |
| Baseline Drift Filter | 0.5 Hz(-3 dB) |
Memory & Interface
| Item | Parameter |
|---|---|
| Patient Storage | Max. 200 patient reports |
| Communication Port | USB, RS232 |
Environmental
| Item | Parameter |
|---|---|
| Operating Temperature | 5 ℃–40 ℃ |
| Operating Humidity | 15%–95% non-condensing |
Power Requirement
| Item | Parameter |
|---|---|
| AC Input | 110–230 V~, 50/60 Hz |
| Battery | Built-in 6000 mAh rechargeable lithium-ion battery, 4-hour continuous operation |
Clinical Applications
Built for hospitals, community clinics, physical-examination centers, and out-of-hospital mobile medical services—delivering reliable 12-lead ECG acquisition wherever screening, triage, or follow-up care is needed, with dual AC-DC power and local data storage supporting seamless workflows across bedside, outpatient, and field settings.
Comprehensive score