What is noninvasive blood pressure (NIBP)?
author: Myra
2023-09-28
|
The measurement method of NIBP
The NIBP measurement method of multi-parameter monitor is generally the oscillation method, and its principle is as follows: The cuff tied to the arm is used to inflate the cuff with an air pump to block the propagation of the pulse in the blood vessel. When the pressure reaches a certain level (generally 124~316kPa), the blood flow can pass through the blood vessel, and there are certain oscillating waves, which gradually deflate and the oscillating waves become larger and larger. As the contact between the cuff and the arm becomes looser and looser, the pressure and fluctuations detected by the pressure sensor become smaller and smaller, and the pressure sensor can detect the pressure and fluctuations in the cuff in real time. We assume that the moment of maximum fluctuation is selected as the reference point, and based on this point, the fluctuation point of peak 0.45 is found forward. This point is the high pressure (i.e., the systolic pressure), looking back is the fluctuation point of the peak 0.75, which corresponds to the low pressure (i.e., the diastolic pressure), and the point with the highest fluctuation corresponds to the average pressure. ![]() Advantages and disadvantages of NIBP
1.Advantages
2.Disadvantages
![]() Factors affecting the correct measurement of NIBP
1.Arm clothing thickness
Studies have shown that the systolic and diastolic blood pressure values measured by every layer of clothing with a thickness of less than 0.5cm are significantly higher than those measured by standard methods, with an average difference of 12.5 mmHg in systolic blood pressure and 8.3mmHg in diastolic blood pressure. 2.The selection standard of the cuff Cuff width is another important factor affecting the accuracy of non-invasive blood pressure monitoring. Patients with different arm girth should use different armbands to measure blood pressure. This is determined by the principle of non-invasive blood pressure monitoring. 3.Differences in blood pressure measurements of different postures The study found that there was no statistically significant difference between the blood pressure of the ipsilateral upper limb in the lateral position and that of the horizontal upper limb, while the blood pressure of the opposite upper limb was lower than that of the horizontal position, with statistically significant difference. If you would like to learn more about the professional equipment for measuring NIBP, please visit our website——www.chinautech.com. |
Measurement of Blood Oxygen
How to use Pulse oximeter? Does it works?
Related Article

Can asthma go away? Learn about asthma remission, genetic factors, symptoms, asthma cough, and the warning signs of life-threatening status asthmaticus.
Can Asthma Go Away Completely?
Explore tHIS ASEAN 2026, Southeast Asia’s leading healthcare exhibition connecting global medical technology providers with regional distributors, hospitals, and healthcare professionals. Discover ASEAN healthcare market growth, medical device opportunities, patient monitoring systems, pulse oximeters, AI healthcare, remote patient monitoring, and emerging trends shaping the future of healthcare across Southeast Asia.
tHIS ASEAN 2026: Southeast Asia Healthcare Exhibition and Medical Device Opportunities
Recent Ebola outbreaks in Africa have highlighted ongoing challenges in infectious disease control and healthcare preparedness.
Ebola Outbreaks in Africa: Clinical Challenges, Supportive Care, and the Role of Patient Monitoring
An article to discover how AI-driven semiconductor demand is increasing patient monitor manufacturing costs. Learn how supply chain pressures, component shortages, and regulatory requirements are reshaping medical device pricing.
Why Is AI Making Medical Devices More Expensive? A Patient Monitor Case Study