0
```html
Header Banner PM6000 PATIENT MONITOR
Description
Bring an Easy Way to Monitoring
Patient monitoring should be more equitable and inclusive. Based on 16-year experience of UTECH patient monitoring, PM senies patient monitors, precise target to pimary clinical demands, ensure high qualty, durability, and accuracy affordably. Elevate operation experence and performance on the premise of cost control.
Sleek Design PM6000 PATIENT MONITOR
Sleek Design, Intelligent Monitoring
The design of this monitor is a fusion of meticulous craftsmanship and refined aesthetics.

Every detail has stood the test of scrutiny, and the overall appearance is seamless and harmonious.

It transforms the complex medical data into an intuitive visual presentation.
Customized Options PM6000 PATIENT MONITOR
Customized Options
Transform this monitor into your central critical care hub.

Beyond standard parameters, you can configure advanced modules for EtCO₂ and IBP monitoring, capturing a complete physiological picture.

Coupled with an intuitive touch interface and an onboard printer for rapid report generation, you have an agile system that puts comprehensive data and control at your fingertips, streamlining complex workflows.
Central Monitoring PM6000 PATIENT MONITOR
Central Monitoring Compatible
The PM6000 is equipped with advanced connectivity options, allowing it to be seamlessly integrated into a Central Monitoring System.

This enables the real-time wireless transmission of patient data, facilitating streamlined data management.
Features of Patient Monitor
  • 12.1"large-sized screen,anti-dazzle with 4°incline.
  • Integrated module designs ensure the product's safety,stability and durability.
  • Wide-angle alarms indicator makes patients safer.
  • Multiple display modes:OxyCRG,Trend table andTrend graph etc.
  • Advanced patient information management system.
  • Review trend data at any time for any patient by inputting patient ID or name.
  • Connect with central monitoring system for remote and wireless monitor.
  • High capacity storage,power-off data protection.
  • 3-level visual/audio alarms and alarm events can be stored and reviewed.
  • Support slot interfaces:Network,Wi-Fi.
Specifications
Display
LCD, 12.1 inch diagonal, high-resolution TFT (Thin Film Transistor) Active Matrix LCD
Resolution, 1024 X 768 pixels
SpO2
Range, 0-100% Functional Saturation
Accuracy, ± 2 bpm or ± 2% of reading (whichever is greater)
Resolution, 1 %
Pulse Rate Range, 20 bpm to 350 bpm
Pulse Rate Accuracy, ± 2 bpm or ± 2% (whichever is greater)
Resolution, 1 bpm
ECG
Lead Set, 3-lead: I, II, III 5-lead: I, II, III, V, aVR, aVL, aVF 12-lead: I, II, III, V1, V,2 V3, V4, V5,V6, aVR, aVL, aVF
HR range, 20-350 bpm
Heart Rate Accuracy, ±2 bpm or ±2% (whichever is greater)
Resolution, 1 bpm
Gain Selection, X 1/4, X1/2, X1, X2, X4,auto
Sweep Speed, 6.25 mm/s; 12.5 mm/s; 25mm/s; 50 mm/s
NIBP
Method of Measurement, Oscillometric with step-down deflation
Range Systolic: (40 to 270) mmHg; Mean Arterial: (30 to 220) mmHg, Diastolic: (20 to 200) mmHg
Units of Measure, mmHg, kPa(user-select able)
Resolution, 1 mmHg
Measurement Time, 30 s to 50 s typical, 120 s maximum
Default Inflation Pressure, 165 mmHg - Adult 145 mmHg - Pediatric 90 mmHg - Neonate
Cuff pressure rating, (0 to 300) mmHg
Over pressure protection, Adult: 297±3 mmHg Pediatric: 297±3 mmHg Neonate: 147±3 mmHg
TEMP
Standards, (ISO 80601-2-56)
Method, Thermal resistance
Channel, Two channel
Range, 0℃ to 50℃ / 32℉ to 122 ℉
Accuracy, ± 0.2 ℃ plus the temperature sensor tolerance
Resolution, 0.1 ℃, 0.1℉
TEMP Alarm Range, High: 35.5 ℃ to 43.5 ℃ and OFF in 0.1 Increments; Low: 35.5 ℃ to 43.5 ℃ and OFF in 0.1 Increments
CO2 (Optional)
Mode of Sampling, Main stream
Sample Flow Rate, Range: (50 to 150) ml/min Accuracy: ±20%; Default: 75 ml/min
Principle of Operation, Non-dispersive infrared, dual Wavelength, no moving parts.
Initialization Time, Capnogram displayed in less than 4 seconds, At an ambient temperature of 25℃, full specifications within 5 minutes.
CO2 Measurement Range, (0 to 114)mmHg, (0 to 15)% , (0 to 15.2 )kPa
CO2 Response Time, Includes transport time and rise time Less than 2 seconds,at 150ml/min sampling flow Less than 3 seconds,at 100ml/min sampling flow Less than 4 seconds, at 50ml/min sampling flow
CO2 Resolution, 0.1 mmHg
CO2 Accuracy, (0 to 40) mmHg ±2 mmHg (41 to 70) mmHg ±5% of reading (71 to 114) mmHg ±10% of reading Above 80 breaths per minute ±12 % of reading * Note: Gas temperature at 25 ℃
CO2 Stability, Short Term Drift: Drift over three hours shall not exceed 1 mmHg maximum.Long Term Drift: Accuracy specification will be maintained over a six hour period
Sampling Rate, 100 Hz
Respiration Rate Range, (4 to 150) breaths per minute
Respiration Rate Accuracy, ±1 rpm
Calibration, No routine user calibration required.
Respiration
Range,0 to 120rpm
Accuracy,±1 rpm
Resolution,1 rpm
RESP Alarm Rang,High: 0 rpm to 120 rpm , and OFF Low: 0 rpm to 120 rpm , and OFF
Lead,Lead Ⅱ
Environmental
Temperature, (0 to 50) ℃ (Operating) (-20 to +55) ℃ (Storage and Transport)
Humidity, 15% to 95% (Operation) 10% to 95% (Storage and Transport)
Barometric Pressure, (70 to 106) kPa (Operation , Storage and Transport)
Power Requirement
AC Input, (100 to 240)V a.c., 50/60 Hz, 60VA, FUSE T1.5A
Rechargeable battery, 11.1V, 4.4mAh