IP300 VET INFUSION PUMP
It supports rate, time, dose, sequential and drug‑library infusion modes, along with bolus, purge and KVO functions. Equipped with audio‑visual alarms and built‑in rechargeable battery, it also offers optional warmer and WiFi modules. Its flow rate ranges from 0.1‑1500 ml/h with ±4.5% accuracy within 12 hours. Rated IPX4 for splash‑proof, the pump has a 7‑year service life. Operators shall respond promptly to device alarms.
Description
High-precision Veterinary Infusion Control
The IP300V veterinary infusion pump delivers stable and accurate fluid administration with a flow rate accuracy of ±4.5%. It supports a wide flow range to match the physiological characteristics of different animal species, effectively reducing risks such as over-infusion and insufficient dosing.

Diversified Modes & Flexible Configuration
The system supports infusion modes including infusion rate, duration, dose, sequence (optional), and drug library (optional); these modes can be switched with a single press of the"Mode"button.
The dose mode allows dose calculation based on animal body weight (0.1–300 kg), making it suitable for animals of varying boy sizes.

Multi-layer Safety Protection & Portable Design
Equipped with a complete intelligent alarm system and pressure blocking detection, it monitors the infusion status in real time. Built-in rechargeable battery supports mobile use, suitable for on-site transfer and emergency treatment of animals.
Features
- Multi‑infusion mode: Rate / Time / Dose / Sequence (optional) / Drug Library (optional); switch modes with a single press of the Mode key.
- Manual and automatic bolus dosing functions enable rapid drug administration.
- Purge function: rapidly discharge air from the piping system.
- For the KVO intravenous open mode, after completion of infusion, maintain patency of the access line at a rate of 0.1–20 ml/h.
- The infusion flow rate can be adjusted in real time to meet clinical needs.
- Drop rate sensor (optional): automatically detects and counts drops to monitor the infusion rate.
- Pipeline heater (optional, 30–50 °C) warms the infusion fluid to reduce irritation to the animal.
- WiFi (optional, 2.4 GHz) uploads the operating status of the device to the infusion monitoring system.
- Intelligent tiered alerts: bubbles, blockage, absence of medicinal fluid, low battery level, free flow, etc.; alerts can be silenced or cleared.
- 10‑level brightness adjustment, multilingual interface, and support for storing and exporting up to 5,000 historical records.
Specifications
| Parameter items | parameter values |
|---|---|
| Infusion flow rate | 0.1–1500 ml/h (step sizes: 0.01 / 0.1 / 1 ml/h) |
| Drop rate setting | 1–400 drops/min |
| Infusion accuracy | ±4.5% (12 h, 1 L infusion, compliant with EN/IEC 60601‑2‑24) |
| Intravenous fluid volume (VTBI) | 0.0~9999.9 ml |
| Infusion duration | 00:00:01~99:59:59(hh:mm:ss) |
| Piping flow rate | 0.1–1500 ml/h (default: 600 ml/h) |
| Infusion rate | 0.1~1500 ml/h |
| Push volume | 1.0~100.0 ml |
| KVO speed | 0.1~20 ml/h |
| Parameter items | parameter values |
|---|---|
| Volume of medicinal solution | 0.1–999.9 (Units: g / mg / U / IU) |
| dosage | 0.001~9999 |
| Animal body weight | 0.1~300.0 kg |
| Quality of the medicinal solution | 0.1~9999.9 ml |
| Parameter items | parameter values |
|---|---|
| Obstruction pressure rating | 14 pressure stages (30–160 kPa, with an error of ±15 kPa per stage) |
| Maximum blocking pressure | 200 kPa |
| Bubble Detection | Single bubble: 15–1000 μl; cumulative volume: 0.1–2 ml per 15 min |
| Parameter items | parameter values |
|---|---|
| alternating current power supply | 220 V, 50 Hz, with ground fault protection |
| fuse | F2AL/250 V ×2 |
| maximum power dissipation | 60 VA |
| power line | 2.5 m |
| Parameter items | parameter values |
|---|---|
| type | Lithium polymer battery, 7.2 Vdc, 2600 mAh (approx. 120 g) |
| duration of flight | Approximately 5 hours (at flow rates of 25 ml/h and below); approximately 4 hours at maximum flow rate |
| charging interval | Power‑off duration <10 h; Power‑on duration <14 h |
| Parameter items | parameter values |
|---|---|
| main engine | 120 × 100 × 215 mm (excluding column clamps), approximately 1.5 kg |
| pack | 248 × 190 × 155 mm, approximately 2.1 kg |
| Parameter items | parameter values |
|---|---|
| working temperature | 5~40 ℃ |
| Working humidity | 20%–80% (no coagulation) |
| atmospheric pressure | 70~106 kPa |
| Parameter items | parameter values |
|---|---|
| safety standards | IEC 60601‑1 / 60601‑2‑24 / 60601‑1‑2 / 60601‑1‑8 / IEC 60529 |
| levels of protection | IPX4 (Spill‑proof) |
| Application Components | Defibrillation CF‑type application component |
| Electrical Type | Class I devices |
| Installation column diameter | 15~36 mm |